Posted by N8N on January 22, 2010, 4:33 pm
 
please rate
this thread



No, in a semi-pernanent installation you will have something like this
next to your main breaker panel

http://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_20032103=
3_200321033

you only need one big 240VAC cord to make this work.  sized for the
total load that will be on the generator.

nate


Posted by RBM on January 22, 2010, 4:40 pm
 



The transfer switch that Nate links to is probably the cheapest, easiest
method of connecting a generator to your electric service, and  won't take
an electrician more than an hour to connect. Note: the one shown has a
thirty amp twist lok


Posted by Ralph Mowery on January 22, 2010, 4:44 pm
 



When you have a transfer switch installed, you run one cable to the
generator.  It will usually have 4 wires in it and they will all go into the
240 volt plug.  The older unit will have a 3 wire plug.  Two of the wires
will be to the hot wires, one to the neutral, and the other one if used will
be a chassies ground.
The power will be split as needed at the box at the house.

Diesel will probably be the best.  It lasts for many years unlike gas.  Also
you will probably want to run the generator for short periods of time every
couple of weeks or so.  Gas tends to wash the oil from the piston rings and
get into the crankcase oil during the short run periods.




Posted by Stormin Mormon on January 22, 2010, 7:23 pm
 

Can't say as I've ever heard that.

--
Christopher A. Young
Learn more about Jesus
  www.lds.org
.



Gas tends to wash the oil from the piston rings and
get into the crankcase oil during the short run periods.





Posted by PeterD on January 23, 2010, 8:36 am
 

On Fri, 22 Jan 2010 19:23:36 -0500, "Stormin Mormon"


It can happen, if the engine is not allowed to fully warm up during
the test runs. Diesels can also 'cold stack' if run without a load for
an extended period of time. (some are more prone to doing this than
others, but generally any emergency generator should be run under load
when exercising it, to ensure that the entire system works properly).